pH-METER, CONDUCTIMETER, TDS, ºC - MULTIPARAMETRIC PORTABLE. Models PC 7+ and PC 70+
Ergonomic model. Supplied in case with electrode and solutions. Equipped with rubber protective cover and a large LCD display showing all data simultaneously.
pH - mV/ORP - COND - TDS -Temperature for the model PC 7+.
GLP - Data Logger -USB additional for the model PC 70+. 5 years warranty
Specifications |
Model PC 7 |
Model PC 70 |
Range pH |
0,00 to14,00pH |
-2 to16,00pH |
Resolution |
0,1 / 0,01pH |
0,1 / 0,01pH |
Calibration points |
1, 2 or 3 |
|
Reconigzed bufferes |
USA: 1,68-4,01-7,00-10,01 NIST: 1,68-4,01-6,86-9,18pH 1 user-defined value |
|
Indication of slope and asymmetry potential |
YES |
YES with date and hour |
GLP Function |
- |
YES |
Indication as stable measure |
YES |
|
Timer calibration |
- |
YES |
Indication of buffer calibration |
YES |
YES |
Range of mV |
± 1.000mv |
± 1.999mv |
Resolution |
1mV |
0,1mV (±200mV) / 1mV |
Range COND |
0,0 to199,9mS |
|
Resolution |
0,01/0,1/1µS 0,01/0.1mS |
|
Calibration points |
1…4 |
|
Recognized standards |
84µS – 1413µS – 12,88mS – 111,9mS 1 user-defined value |
|
Cell constant selecable |
0,1 - 1 - 10cm-1 |
|
Reference temperature |
15 to 30ºC |
|
GLP function |
- |
YES |
Calibration timer |
NO |
YES |
Indication of standard used |
YES |
|
TDS range |
0 to100g/l |
|
Resolution |
- |
1% f. e. |
TDS factor |
0,4 to1,0 |
|
Salinity |
NO |
0 to 50 ppt |
Temperature |
0 to100,0ºC |
-10 to110ºC |
Resolution / Accuracy |
0,1ºC / ± 0,5ºC |
|
Compensation of temperature pH |
Automatic / manual 0 to100ºC |
|
Compensation of temperature conductivity |
Automatic / manual 0 to 80ºC |
Automatic / manual 0 to 100ºC |
GLP system |
NO |
YES, Data Link |
Data Loger |
NO |
Man / Auto 500 dates with date and hour |
Auto-shutdown |
After 20 minutes |
|
Display |
LCD |
LCD back-light, 3 colors |
Input |
2xBNC and Tem Cinch |
2xBNC, Temp Cinch and USB(PC) |
Power |
3 batteries 1.5V AA |
3 batteries 1.5V AA Power pack AC/DC with cable USB |
Autonomy |
>300 hour |
|
Protection IP |
Anti moisture IP 57 |
|
Size / weight of instrument |
86 x196 x 33mm / 295g |
86 x196 x 33mm / 300g |
Size / weight with suitcase |
385 x 300 x 115mm / 1720g |
385 x 300 x 115mm / 1725g |
4.0111.00 | PC7 - pHmeter/Conductimeter/TDS/Temperature, portable, with pH electrode, conductivity cell/CAT,suitcase,dissolutions |
---|---|
4.0111.01 | PC7 - Multiparametric like above without pH electrode |
4.0105.00 | PC70 - pHmeter/Conductimeter/TDS/Temperature portable, with ph electrode, conductivity cell/CAT,suitcase,dissolutions |
4.0105.01 | PC70 - Multiparametric like above without pH electrode |
4.0100.30 | Electrode, epoxi body, 1m cable |
4.0104.02 | Cell of conductivity(5µS…100mS) plastic, 0...80ºC, with CAT 1m cable |
4.0104.07 | Cell K=0.1(1uS...1mS) epoxi/st.st.with CATNTC 30K, 0...80ºC 1m cable BNC |
BENCH-TOP MULTIPARAMETRIC MODEL PC52 pH /mV / Conductivity /ºC
♦Microprocessor
♦Automatic and manual calibration
♦Custom configuration
♦Automatic and manual calibration with automatic knowledge of 4 standards and 1 to defined by user
♦Automatic compensation of temperature
♦Cell constant: 0.1 – 1.0 – 10.0 selectable
♦ Automaticscalinginavoidingerrors
♦Temperature coefficient: 0.00 to 9.99% by ºC adjustable
♦Reference temperature: 15…30ªC
♦Indication of Slope and Offset
♦Screen: LCD back-light
♦Display information about reading stability and auto-diagnostic
ESPECIFICATIONS
♦Scales: 0,00 -14,00pH / ±1000mV /0,0…200-2000µS / 20,00-200,0mS (± 1% deep scale) / 0…100º( 0,1ºC/±0,5ºC)
♦Resolution: 0,1/0,01 pH / 1mV /0,1/1µS, 0,01/0,1mS / 0,1ºC
♦Recognize standards: 84, 1413µS and 12,88, 111mS and 1 point defined by user, 25ºC
♦Calibration points: 3 points recognized on screen, standards USA 1,68 /4,01 / 7,00 /10,01pH and NIST, 1,68 / 4,01 / 6,86 / 9,18pH and 2 points defined by user.
♦Inputs: 2 BNC and 2 RCA / Jack (CAT) and REF
♦Power: 5V DC / 220V AC, power pack
♦Size / Weight: 160 x 185 x 70mm/550g
4.0113.00 | Bench-top multiparametric 52, articulate support, standards, pH electrode and cell /CAT |
---|---|
4.0113.01 | Bench-top multiparametric 52 with articulate support, standards, pH electrode without cell |
4.0104.02 | Cell of conductivity(5µS…100mS) plastic, 0...80ºC, with CAT 1m cable |
4.0104.03 | Cell 5µS to 150mS, 0…80ºC CAT NTC30, glass,1m cable |
4.0104.04 | Cell (0.1uS...500µS) with CAT NTC30, epoxi/st.st., 1m cable. |
4.0200.14 | Articulate support for 4 sensors and CAT |
4.0101.05 | Electrode, plastic Polyplast-HAMILTON,0…14 pH,0…60ºC,electrolyte gel,head thread S7 |
---|---|
4.0101.06 | Electrode,plastic Polyplast-HAMILTON, 0…14 pH, 0…60 ºC, electrolyte gel,with 1m fixed cable BNC |
4.0100.30 | Electrode, epoxi body, 1m cable |
4.0101.11 | Electrode POLYLITE LAB,0-14 pH, 0…80 ºC, glass body,electrolyte polymer. |
4.0101.10 | Electrode LIQ-GLASS. 0...14pH, -10...100ºC, glass body, electrolyte liquid |
4.0101.12 | Electrode DOUBLE PORE, penetration Ø 6 mm,L = 25 mm,0…14 pH, 0…60ºC,glass body |
4.0101.13 | Electrode FOODTRODE,2…14 pH,-10…100ºC,glass body,electrolyte liquid Protelyte |
4.0101.16 | Electrode FLUSHTRODE, difficult measures, 0…14 pH,10…50 ºC, glass, electrolyte liquid |
4.0101.20 | Electrode SINGLE PORE GLAST, 0...14 pH, 0…100ºC, glass body, electrolyte liquid |
4.0101.21 | Electrode FLATRODE, for.surfaces,0…14 pH,0…80ºC,epoxi body, electrolyte liquid |
4.0101.22 | Electrode SLIMTRODE,microØ6 mm y 100mm,0…14pH,0…80ºC, glass body, electrolyte liquid |
4.0101.23 | Electrode MINITRODE,micro Ø3 mm y 60mm,0…14pH,0…80ºC, glass body,,electrolyte liquid |
4.0101.26 | Electrode, double redox Pt, LIQ-GLASS ORP, -5…100 ºC |
4.0101.27 | Electrode, double redox Pt, for. portables, POLYPLAST RX, epoxi body , 0…60 ºC, 6 bar |
4.0101.28 | Electrode, double of Silver, LIQ-GLASS AG, -5…100 ºC, electrolyte KNO3 1M |
4.0101.29 | Electrode Ag/AgCl, double bridge, with fixed cable and connector with 2 sticks of 2.5 mm Ø |
4.0101.30 | Cable AS7/ 1M / BCN, for pHmeters with BNC connector |
---|---|
4.0101.31 | Cable AS7 / 1M /stik 4 mm for reference electrodes |
4.0101.48 | Standard redox 475 mV, 1x500 ml |
---|---|
4.0101.49 | Standard redox 200 mV, 1x250 ml |
4.0101.32 | 4.01 ± 0.01 pH / 25 ºC, 1x500 ml |
---|---|
4.0101.36 | 7.00 ± 0.01 pH / 25 ºC, 1x500 ml |
4.0101.40 | 10.00 ± 0.01 pH / 25 ºC, 1x500 ml |
4.0101.43 | 4.01 ± 0.01 pH / 25 ºC, 1x70 ml |
4.0101.45 | 7.00 ± 0.01 pH / 25 ºC, 1x70 ml |
4.0101.46 | 10.00 ± 0.01 pH / 25 ºC, 1x70 ml |
4.0101.53 | KCl 3M, 1x55 ml |
---|---|
4.0101.54 | KCl 3M, 1x500 ml |
4.0101.58 | KNO3 1 M, for Silver electrodes 1x55 ml |
4.0101.59 | Lithium Acetate 3M, 100 ml |
4.0101.60 | Maintenace/conservation of electrodes , 1x500 ml HAMILTON |
---|---|
4.0101.61 | Clean-proteins (Pepsine-HCl) 1x250 ml |
4.0101.62 | Clean - diaphragms (Thiourea+HCl) 1x250 ml |
4.0101.63 | Regeneration of membranes, 55 ml |
4.0100.13 | Standard 1.3 μS/cm/25%C, 1x300 ml . Trazeability DKD |
---|---|
4.0100.14 | Standard 5 μS/cm/25%C, 1x300 ml . Trazeability DKD |
4.0100.15 | Standard 15 μS/cm/25%C, 1x300 ml . Trazeability NIST |
4.0100.16 | Standard 84 μS/cm/25%C, 1x500 ml . Trazeability NIST |
4.0100.22 | Standard 100 μS/cm/25%C, 1x300 ml . Traceability NIST |
4.0100.11 | Standard 147 μS/cm/25%C, 1x500 ml . Traceability NIST |
4.0100.04 | Standard 1413 μS/cm/25%C, 1x500 ml . Trazeability DKD |
4.0100.07 | Standard 12.880 mS/cm/25%C, 500 ml . Trazeability NIST |
4.0100.21 | Standard 100 mS/cm/25%C, 1x300 ml . Traceability NIST |