Peristaltic Pumps Multi-Heads
Peristaltic Pumps Model D-25Vxi
♦ Numeric speed control that can be set 0 - 99% in 1% increments with 100% repeat accuracy by pump head.
♦ Remote control by foot switch or external relay
♦ 4 Available Pump heads of easy charge tubes with 3 or 4 rollllers and motorreducers from 30 to 350 rpm
♦ Switch ON/OF/Reverse flow by pump head
♦ Digital cyclic timer allows pumping schedule and shutdown times of 0,01 seconds at 99,90 hours which makes it possible to obtain any volume in each cycle of the timer
♦ Speed control by optional signal 0-10 volts. Consult this option.
♦ Pumps accept several tube sizes. Tubing is easily removed for changeover, or autoclaving.
♦ Pumps with multiple heads adapted to the needs of the user are manufactured.
Pump Codes. Indicative flows rates by channel
Code ▼ |
Model |
Pump Head |
Timer |
Flow ml/min |
Motor rpm |
1.9733.14 |
D25V2i |
2 x CFG1-3r |
No |
5.0 to 565 |
300 |
1.9733.15 |
D25V2i |
2 x CFG2-3r |
0.5 to 175 |
300 |
|
1.9733.40 |
D25V2i |
2 x CF-4r |
2.0 to 1100 |
350 |
|
1.9733.13 |
D25V2i |
2 x CFV-4r |
0.2 to 30 |
30 |
|
0.5 to 80 |
80 |
||||
2.0 to 220 |
240 |
||||
1.9733.16 |
D25VT2i |
2 x CFG1-3r |
Yes
|
5.0 to 565 |
300 |
1.9733.17 |
D25VT2i |
2 x CFG2-3r |
0.5 to 175 |
300 |
|
1.9733.41 |
D25VT2i |
2 x CF-4r |
2.0 to 1100 |
350 |
|
1.9733.04 |
D25VT2i |
2 x CFV-4r |
0.2 to 30 |
30 |
|
0.5 to 80 |
80 |
||||
2.0 to 220 |
240 |
||||
1.9734.01 |
D25V4i |
4 x CFG1-3r |
No |
5.0 to 565 |
300 |
1.9734.02 |
D25V4i |
4 x CFG2-3r |
0.5 to 175 |
300 |
|
1.9734.08 |
D25V4i |
4 x CFV-4r |
0.2 to 30 |
30 |
|
0.5 to 80 |
80 |
||||
2.0 to 220 |
240 |
||||
1.9734.11 |
D25VT4i |
4 x CFG1-3r |
Yes
|
5.0 to 565 |
300 |
1.9734.12 |
D25VT4i |
4 x CFG2-3r |
0.5 to 175 |
300 |
|
1.9734.10 |
D25VT4i |
4 x CFV-4r |
0.2 to 30 |
30 |
|
0.5 to 80 |
80 |
||||
2.0 to 220 |
240 |
Size: with 2 pump heads, 32 x 26 x 14cm. Weight: 5 Kg. With 4 pump heads, 26 x 34 x 27cm. Weight: 7 Kg. Operation:100… 240V 50/60Hz.
1.9733.14 | D25V2i - Two pump heads CFG1-3r. Variable flow 5. to 565ml/min by head. |
---|---|
1.9733.15 | D25V2i - Two pump head CFG2-3r. Variable flow 0.5 to 175ml by channel |
1.9733.13 | D25v2i - Two pump heads CFV-4r. Variable flow: 0.2 to 220ml/min. each head |
1.9733.40 | D25V2i - Two pump heads CF-4r.Variable flow 2.0 to 1100ml/min. 350 rpm |
1.9733.16 | D25VT2i - Two pump heads CFG1-3r. Variable flow 5.0 to 565ml/min.by pump head. Cyclic timer |
1.9733.17 | D25VT2i - Two pump heads CFG2-3i.Variable flow 0.5 to 175ml/min by channel. Cyclic timer |
1.9733.04 | D25VT2i - Two pump heads CFV-4r. Variable flow 0.2 to 220ml/min each pump head. Cyclic timer |
1.9733.41 | D25VT2i - Two pump heads.CF-4r.Variable flow 2.0 to 1100ml/min. each pump head. Cyclic timer |
1.9734.01 | D25V4i- Four pump heads CFG1-3r.Variable flow 5.0 to 565ml/min. each pump head. |
1.9734.02 | D25V4i - Four pump heads CFG2-3r.Variable flow 0.5 to 175ml/min each channel |
1.9734.08 | D25V4i - Four pump heads CFV-4r. Variable flow 0.2 to 220ml/mi, each pump head |
1.9734.11 | D25VT4i - Four pump heads CFG1-3r.Variable flow 5.0 to 565ml/min.each pump head.Cyclic timer |
1.9734.12 | D25VT4i - Four pump heads CFG2-3r.Variable flow 0.5 to 175ml/min each channel.Cyclic timer |
1.9734.10 | D25VT4i - Four pump heads CFV-4r.Variable flow 0.2 to 220 ml/min,each pump head. Cyclic timer |