Spectrophotometer Ultraviolet-Visible Double Beam
Spectrophotometer UV/VIS Double Beam Model UV6900
Spectrophotometer belonging to a new generation of dual-beam instruments with 2 detectors that simultaneously measure the reference and the sample to optimize accuracy, sensitivity, low stray light and a bandwidth of up to 0,5 nm.
A suitable instrument for clinical, pharmaceutical and biochemical laboratories as well as current applications and quantitative analysis, kinetics, scannings at various wavelengths and analysis of DNA / Protein. All operable directly on the instrument and displayed on the LCD display or transferred to PC, data, and curve.
♦ Auto - calibration baseline, wavelength and dark current
♦ Equipped with parallel printer port and one USB for PC. Included software
♦ Available a variety of accessories to complete the versatility of the spectrophotometer.
♦ New layout monochromator diffraction grating with 1200 lines which ensures high durability and stability of the system
♦ Software Update by internet
♦ Real-time results, date and time
♦UV / VIS 6900A version in compliance with the requirements of the European Pharmacopoeia including software according to 21CFR11 criteria
♦ 320x240mm LCD big screen
SOFTWARE UV/VIS ANALYST (included). Features
Multi - Wavelength
Up 32 wavelengths can be selected and multiple samples can be measured
Quantitative
1- Coefficient method
2- Standard curve
Up to 10 standards samples may be used to establish a curve. Four methods for fitting a curve through the calibration points: Linear fit, Linear fit through zero, Square fit and Cubic fit
Wavelength Scan
1- The wavelength scan intervals are:0,1-0,2-0,5-1,0-2,0-5,0
2- Scan speed: High - Medium and Low, from 100 to 3000nm/min.
DNA /Protein Test
Concentration and DNA purity are quickly and easily calculated:
Absorbance ratios 260nm / 280nm with optional subtracted absorbance at 320nm
DNA concentration = 62,9 x A260 - 36,0 x A280
Protein concentration= 1552 x A260 - 757,3 x A280
Kinetics
Calculate reaction rates. Graphical time / real time absorbance
Total time up to 12 hours with reading selectable interval 0,5 -1 - 2 - 5 - 10 - 30 seconds and 1 minute
Further manipulation with re-scaling, curve tracking and selection of the part of the curve required for the rate calculation
The speed is calculated using a linear regression algorithm before multiplying by the factor entered
| Parameters | Features | Parameters | Features |
|---|---|---|---|
| Optical principle | Double beam | Baseline flatness | ±0,001Abs |
| Wavelength range | 190-1100nm | Noise | ±0,001 Abs |
| Wavelength accuracy | ±0,3nm | Band width | 0,5/1,0/2,0/4,0 to select or 1,8 |
| Wavelength repeatability | ±0,2nm | Stray light | <0,05%T(220nm,360nm) |
| Photometric accuracy | ±0,3%T | Out | USB |
| Measuring ranges | Abs: -0,3 to 3,0 %T: 0 to 200%T Conc: 0 to 9999C |
Baseline stability | 0.002Abs/h (at 500nm, after 2h warm up |
| Photometric repeatability | ±0,2%T | Light source | WI, D2 |
| Instrument control | Autonomous and PC | Detectors | Silicon photodiodes |
| Weight | 30Kg | Printer port | Parallel |
| Power | 220VAC 50/60Hz | Size | 625wx430dx206h mm |
| 6.8000.00 | Spectrophotometer Double Beam UV/VIS X-8 Smart Touch Screen.Bandwidth 0,5-1-2-4 nm. |
|---|---|
| 6.8000.18 | Spectrophotometer Double Beam. UV/VIS, X-8. Smart Touch Screen. Bandwidth 1,8 nm |
| 6.8000.20 | Spectrophotometer UV/VIS. X-8. Double Beam.Smart Touch Screen. Bandwidth 1.0 nm |
| 6.3000.02 | Optional PC software to comply with 21 CFR PART 11 |
| 6.6900.03 | Halogen lamp for visible |
| 6.6900.08 | Deuterium lamp for UV, all models except UV/VIS4000 |
| 6.3200.01 | Cuvette Holder 1x10mm path light |
|---|---|
| 6.3200.02 | Cuvette Holder 4x10mm path light |
| 6.3200.03 | Cuvette Holder 4x50mm path light |
| 6.3200.04 | Cuvette Holder 4x100mm path light |
| 6.6900.02 | 10 mm 8-hole manual cell holder, only for models 3500, 4600, 6000, 6900 and 8000 |
| 6.3000.04 | Cuvette Holder 8 x10 mm path light, automatic (only for 3500, 4600, X-6 and X-8 models) |
| 6.3200.07 | Tube Holder, 20mm max. diameter |
| 6.3200.06 | Films( transparents) Holder |
| 6.3200.05 | Micro Cuvettes Holder, adjustable |
| 6.3200.09 | Sipper System, continuos 1 to 255 s, only for models 3500,4600,6900,6000 and 8000 |
| 6.3200.08 | Peltier System, 15ºC to 65ºC, only for models 3500,4600, 6000, 6900 and 8000 |
| 6.3200.10 | Peltier/Sipper System, only for models 3500,4600,6000, 69000 and 8000 |
| 6.6900.07 | Micro-printer for dates |
| 8.9749.00 | PC computer with 24´´ LED screen |
| 6.3200.17 | Cuvette holder 1x10 mm path light for water recirculation |
| 6.3200.11 | Cuvette with lid, glass 1.7ml, 5mm path light, 4pcs |
|---|---|
| 6.6900.05 | Cuvette with lid, glass 3.5ml, 10mm path light, 4pcs |
| 6.3200.12 | Cuvette with lid, glass 7ml, 20mm path light, 4pcs |
| 6.3200.13 | Cuvette with lid, glass 10.5ml, 30mm path light, 4pcs |
| 6.3200.15 | Cuvette with lid, glass 17.5ml, 50mm pat light, 4pcs |
| 6.3200.16 | Cuvette with lid, glass 35ml, 100mm pat light, 4pcs |
| 6.4000.01 | Cuvette wit lid, quartz 1.7ml, 5mm path light, 2pcs |
| 6.6900.06 | Cuvette with lid, quartz 3.5ml, 10mm path light, 2pcs |
| 6.4000.02 | Cuvette with lid, quartz 7ml, 20mm path light, 2pcs |
| 6.6400.03 | Cuvette with lid, quartz 10.5ml, 30mm path light, 2pcs |
| 6.4000.05 | Cuvette with lid, quartz 17.5ml, 50mm path light, 2pcs |
| 6.4000.06 | Cuvette with lid, quartz 35ml, 100mm path light, 2pcs |
| 6.4000.07 | Micro Cuvette, quartz 12.5*12.5*45*, 100ul, 2pcs |
| 6.4000.08 | Micro Cuvette, quartz 12.5*12.5*45*, 200ul, 2pcs |
| 6.4000.10 | Micro Cuvette, quartz 12.5*12.5*45*, 700ul, 2pcs |
| 6.6900.03 | Halogen lamp for visible |
| 6.6900.04 | Deuterium lamp for UV, model UV/VIS4000 |
| 6.6900.08 | Deuterium lamp for UV, all models except UV/VIS4000 |